Actions
Does Channel Exist |
Return true if the identifier is a valid channel. Target is Timed Data Monitor Subsystem |
Get Channel Buffer Overflow Stat |
Returns the number of buffer overflows detected by that input since the last reset. Target is Timed Data Monitor Subsystem |
Get Channel Buffer Underflow Stat |
Returns the number of buffer underflows detected by that input since the last reset. Target is Timed Data Monitor Subsystem |
Get Channel Connection State |
Get the state the channel. Target is Timed Data Monitor Subsystem |
Get Channel Data Buffer Size |
If the channel does support it, get the current maximum sample count of channel. Target is Timed Data Monitor Subsystem |
Get Channel Display Name |
Return the display name of an input. Target is Timed Data Monitor Subsystem |
Get Channel Evaluation Distance to Newest Sample Mean |
Returns the average distance, in seconds, between evaluation time and newest sample Target is Timed Data Monitor Subsystem |
Get Channel Evaluation Distance to Newest Sample Standard Deviation |
Returns the standard deviation of the distance, in seconds, between evaluation time and newest sample Target is Timed Data Monitor Subsystem |
Get Channel Evaluation Distance to Oldest Sample Mean |
Returns the average distance, in seconds, between evaluation time and oldest sample Target is Timed Data Monitor Subsystem |
Get Channel Evaluation Distance to Oldest Sample Standard Deviation |
Returns the standard deviation of the distance, in seconds, between evaluation time and oldest sample Target is Timed Data Monitor Subsystem |
Get Channel Evaluation State |
Get the evaluation state of the channel. Target is Timed Data Monitor Subsystem |
Get Channel Frame Dropped Stat |
Returns the number of frames dropped by that input since the last reset. Target is Timed Data Monitor Subsystem |
Get Channel Input |
Return the input of this channel. Target is Timed Data Monitor Subsystem |
Get Channel Last Evaluation Data Stat |
Retrieves information about last evaluation Returns true if identifier was found Target is Timed Data Monitor Subsystem |
Get Channel Newest Data Time |
Get the channel latest sample time. Target is Timed Data Monitor Subsystem |
Get Channel Number Of Samples |
Get the number of data samples available. Target is Timed Data Monitor Subsystem |
Get Channel Oldest Data Time |
Get the channel oldest sample time. Target is Timed Data Monitor Subsystem |
Is Channel Enabled |
Is the channel enabled in the monitor. Target is Timed Data Monitor Subsystem |
Set Channel Data Buffer Size |
If the channel does support it, set the maximum sample count of the channel. Target is Timed Data Monitor Subsystem |
Set Channel Enabled |
Enable or disable an input from the monitor. The input will still be evaluated but stats will not be tracked and the will not be used for calibration. Target is Timed Data Monitor Subsystem |